Excessive Power Consumption
1
Blower speed too high
Check the blower speed and compare with performance chart
2
Pressure too high
Can be caused by excessive pressure or obstructions in the piping.
Excessive Pressure
Check inlet vacuum and discharge pressure; ensure protection valves are correctly set and operational.
Check there are no obstructions in the pipeline:
Check piping, filter, relief valves, isolation valves and silencer the assure an open flow path
3
Unbalanced or rubbing impellers
Inspect outer casing for hot spots.
Check drive alignment (couplings / belts)
Check internal clearances for contact marks: contact S and A Engineering Services for advice
Can also be caused by a build-up of foreign material
Clean off foreign material
Contact S and A Engineer for blower overhaul.
4
Blocked inlet filter
Clean or change filter
Contact S and A Engineering for replacement filter elements
If you have more questions call us
+44 (0)1204 326 387